bullets/green_new.gifUltrapure water quality - with no reservations!

There are areas in which particularly high demands are placed on the water quality.

In chemical organic or inorganic trace analysis, for example, for TOC measurements and
instrumental methods such as HPLC, ICP-MS and IC.

And the demands are even higher in the life sciences. Freedom from endotoxines and
nucleases is a necessity when preparing, or working with, tissue and cell culture media,
PCR, DNA, or monoclonal antibodies.

The Standard, UF, UV and UV/UF versions of GenPure have already convincingly
demonstrated the benefits of the new system control and the high-precision, USP-complying
conductivity measurement with temperature compensation that can be switched on or off.

 

bullets/green_new.gifTechnical intelligence for reliable processes!

TKA Measurement methods. Highest accuracy and reliability!

Exact dispensing
  • Option of fully automatic volume control over 0.01 to 99.9 Litres for large container filling
Conductivity measurement
  • The cell constants of the two highprecision conductivity measuring cells are individually
    measured out and each value deposited in the system. The electronics are automatically
    calibrated and controlled prior to each measurement.
Temperature measurement
  • Platinum chip temperature sensors with an accuracy of +/- 0.1° C are used here.
    The temperature compensation can be switched off. USP requirements are fulfilled
    and optimal measurement reliability ensured.
Online TOC measurement
  • Real time TOC-monitoring with continual and accurate measurement of the organic content
    of the water within the range 1 - 99 ppb.
Monitoring of the intensity of the UV-radiation
  • A UV-photodiode permanently checks the intensity of the radiation from the UV-lamp. A
    decrease in the UV-intensity that would result in a false TOC-value is readily identifiable from
    the % value shown. The UV-lamp must only be changed when really necessary.

 

bullets/green_new.gifTKA xCAD: extended Control And Dispenser unit

For flexible operation in the lab! Leaves more elbow-room on the lab bench!

With a footprint about the size of an A 4 portrait, GenPure can be stood on the lab bench or, if
preferable, it can be hung on a wall (without the need for extra mounting material).

The space-saving under bench version can have up to three flexible control/dispenser units fitted
to it for use at up to 3 m distance from it. Can be stood on a bench or be even more space-savingly
wall mounted

  • Inclinable operator module for practical handling and good viewing
  • Complete system control and steering via the operator module
  • Turnable and height adjustable dispenser arm with extendable joystick. Action radius 80 cm
  • Ergonomically shaped dispensing pistol provides highly precise volume dosing at the press of a button
  Bilder/GenPureDispenser_02.jpg   Bilder/GenPureDispenser_01.jpg

 

bullets/green_new.gifTechnical details

  TKA GenPure
 
TKA GenPure
UF
TKA GenPure
UV
TKA GenPure
UF/UV
Flow rate, up to: up to 2 l/min up to 2 l/min up to 2 l/min up to 2 l/min
Operating pressure in bar, min/max: 2 – 6 bar 2 – 6 bar 2 – 6 bar 2 – 6 bar
Conductivity:
Resistance at 25 °C:
TOC value:
Bacterial content in KbE/ml:
Particles:
Endotoxines in EU/ml:
0.055 µS/cm
18.2 MΩxcm
5 – 10 ppb
<1
<1
0.055 µS/cm
18.2 MΩxcm
5 – 10 ppb
<1
<1
0,001
0.055 µS/cm
18.2 MΩxcm
1 – 5 ppb
<1
<1
0.055 µS/cm
18.2 MΩxcm
1 – 5 ppb
<1
<1
0,001
Electrical requirements: 230 V / 50Hz 230 V / 50Hz 230 V / 50Hz 230 V / 50Hz
Power consumption: 0.1 kW 0.1 kW 0.1 kW 0.1 kW
Feedwater connector: R 3/4" R 3/4" R 3/4" R 3/4"
Dimensions B x T x H in mm: 372 x 330 x 615 372 x 330 x 615 372 x 330 x 615 372 x 330 x 615
Weight: 22 kg 23 kg 23 kg 23 kg
         
Article no. 08.2202 08.2203 08.2205 08.2204

 

  TKA GenPure UV-TOC TKA GenPure
UV-TOC/UF
Flow rate: up to 2 l/min up to 2 l/min
Operating pressure in bar, min/max: 0.1 – 6 bar 0.1 – 6 bar
Conductivity:
Resistance at 25 °C:
TOC value:
Bacterial content in KbE/ml:
Particles:
Endotoxines in EU/ml:
0.055 µS/cm
18.2 MΩxcm
1 – 5 ppb
<1
<1
0.055 µS/cm
18.2 MΩxcm
1 – 5 ppb
<1
<1
0,001
Electrical requirements: 230 V / 50 Hz 230 V / 50 Hz
Power consumption: 0.1 kW 0.1 kW
Feedwater connector: R 3/4" R 3/4"
Dimensions B x T x H in mm: 372 x 330 x 615 372 x 330 x 615
Weight: 24 kg 25 kg
     
Article no. 08.2206 08.2207

 

 

bullets/green_new.gifGenPure systems incl. xCAD Dispenser

 

  TKA GenPure
 
TKA GenPure
UF
TKA GenPure
UV-TOC
TKA GenPure
UV-TOC/UF
 

with dispenser
bench version

with dispenser
bench version

with dispenser
bench version

with dispenser
bench version

Cat. no.: 08.2222 08.2213 08.2216 08.2217
         
 

with dispenser
wall version

with dispenser
wall version

with dispenser
wall version

with dispenser
wall version

Cat. no.: 08.2222 08.2223 08.2226 08.2227
 
 

 

 

symbole/symbol_pdf_mittel.gif Download Leaflet TKA GenPure TOC

symbole/symbol_pdf_mittel.gif Download Leaflet TKA GenPure with xCAD Dispenser