TKA LabTower AFT
The high-tech complete system
for clinical analyzers.
Uncompromising high purity water quality
(CLSI 1) and guaranteed service.
The particular high purity water quality that clinical
analyzers need
-
TKA LabTower AFT Systems have been specifically
designed to efficiently and reliably supply high purity
water analyzers. -
The high purity water quality they produce fulfills all
specific requirements of the analyzer manufacturers and
supplies with the typical CLSI type I quality standards
(formerly NCCLS).
The benefits in a nutshell!
Optimized performance as a lab supplier!
- A high-performance reverse osmosis module combined with a
long lasting lif ion exchanger and UV flow through sanitization - Two systems, for 20 or 40 litres per hour of high purity water
Compact, well-styled design, mobile!
- Needs no bench space
- 1/4 m2 floor space suffices
- castors for easily moving
Dependable operation!
- 100% certainty of supply given by the integrated emergency
supply via a 20 l ion exchanger cartridge - Pressure reducer with pressure display of pump functioning
- Microprocessor control for automatic operation and the monitoring
of all important parameters - Potential free contact for the evaluation of fault messages
- Leak monitoring via AQUASTOP water control with solenoid
valve (optional)
|
|
Double security!
Maximum operational reliability is given by the integrated “By-pass system”.
Should a system fault occur, the just a flick of the wrist suffices to switch it
to purely ion exchanger operation. The supply of high purity water is then
maintained without interruption, faultfree and independent of the other purification
stages. Guaranteed until service comes. Optional monitoring for leaks with a
sensor that can be freely-positioned. With automatic system shut-off as well as
optical and acoustic signals in case of malfunction.
Technical details
|
TKA LabTower
|
AFT 20 | AFT 40 | |
| Flow rate at 15 °C, l/h: | 20 | 40 | |
| Typical conductivity in µS/cm: | 0.1 – 1 | ||
| Typical resistance in MΩxcm: | 10 – 1 | ||
| Bacterial content in CFU/ml, with sterile filter: | < 1 | ||
| Particles content (0,2 µm) per ml, with sterile filter: | < 1 | ||
| Operating pressure in bar, min./max.: | 2/6 | ||
| Supply voltage: | 230 V/50 Hz | ||
| Power consumption, kW: | 0.25 | ||
| Connector size, male thread: | R 3/4” | ||
| Ambient temperature: | +2 °C – +35 °C | ||
| Dimensions W x D x H in mm: | 450 x 580 x 1500 | ||
| Weight in kg: | 66 | 66 | |
| Article-No.: | 08.4422 | 08.4442 | |